BKSHC - FAULT FINDER PENETRANT GROUP 1 #1075,PART C

  • MSDS: BKSHC
  • Manufacturer: CROWN INDUSTRIAL PRODUCTS CO
  • Product Name: FAULT FINDER PENETRANT GROUP 1 #1075,PART C
  • National Stock Number: 6850-00-062-8315
Product Identification

Product ID:FAULT FINDER PENETRANT GROUP 1 #1075,PART C
MSDS Date:08/03/1989
FSC:6850
NIIN:00-062-8315
Kit Part:Y
MSDS Number: BKSHC

Responsible Party
CROWN INDUSTRIAL PRODUCTS CO
100 STATE LINE ROAD
HEBRON, IL 60034
US

Emergency Phone: 815-648-2424

Info Phone: 815-477-6667 (NIGHT)

Preparer: PATRICK PASICIT

Cage: 92381

Contractor
CROWN INDUSTRIAL PRODUCTS CO
350 HEBRON, IL 60034 US

Telephone: 815-648-2424

Cage: 92381

Ingredients

DISTILLATE, CATALYTIC REFORMER

CAS: 68477-31-6

Fraction By Weight: 51-70%

OSHA PEL 300 PPM

ACGIH TLV: 300 PPM


1-METHYLPYRROLIDONE

CAS: 872-50-4

RTECS: UY5790000

Fraction By Weight: 1-10%


POLYALKYLENE GLYCOL (BUTOXYPOLYPROPYLENE GLYCOL)

CAS: 9003-13-8

RTECS: TR4680000

Fraction By Weight: 11-30%


HYDROCARBON PROPELLANT

CAS: 68476-86-8

Fraction By Weight: 11-30%

OSHA PEL 900 PPM

ACGIH TLV: 900 PPM


NAPHTHALENE (SARA III)

CAS: 91-20-3

RTECS: QJ0525000

Fraction By Weight: 10%

OSHA PEL 10 PPM/15 STEL

ACGIH TLV: 10 PPM/15 STEL; 9192

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: SEVERE EYE IRRITATION. CENTRAL
NERVOUS SYSTEM EFFECTS. CHRONIC: PROLONGED CONTACT MAY CAUSE
DEFATTING OF THE SKIN.
Effects of Overexposure:EYES: SEVERE IRRITATION. SKIN: IRRITATION.
INHALATION: HEADACHE, DIZZINESS, NAUSEA. INGESTION: NOT
ESTABLISHED.
Medical Cond Aggravated by Exposure:NOT ESTABLISHED.

First Aid

First Aid:EYES:FLUSH WITH PLENTY OF WATER FOR 15 MINUTES.IF IRRITATION
PERSISTS SEE DOCTOR. SKIN:WASH WITH SOAP AND WATER.IF IRRITATION
PERSISTS.SEE DOCTOR. INHALATION:REMOVE TO FRESH AIR.GIVE OXYGEN/CPR
IF NEE DED,SEE DOCTOR. INGESTION: DO NOT INDUCE VOMITING.SEE
DOCTOR.

Fire Fighting

Flash Point:N/R, AEROSOL
Lower Limits:1.8
Upper Limits:9.5
Extinguishing Media:USE CARBON DIOXIDE, FOAM, OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
FULL FACED SELF CONTAINED BREATHING APPARATUS. EVACUATE AREA. COOL
FIRE EXPOSED CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:CONTENTS UNDER PRESSURE. CONTAINER MAY
EXPLODE ON HEAT OF FIRE.

Accidental Release

Spill Release Procedures:REMOVE IGNITION SOURCES.EVACUATE
PERSONNEL.VENTILATE.WEAR RESPIRATOR AND PROTECTIVE CLOTHING.ABSORB
IN INERT MATERIAL AND PLACE IN APPROPIATE DISPOSAL CONTAINER.WASH
AREA WITH SOAP AND WATER.

Handling

Handling and Storage Precautions:DO NOT STORE IN DIRECT SUNLIGHT, NEAR
OPEN FLAMES, OR AT TEMPERATURES EXCEEDING 120F. DO NOT SMOKE WHILE
SPRAYING.
Other Precautions:USE ONLY AS DIRECTED. INTENTIONAL MISUSE BY
DELIBERATELY CONCENTRATING VAPORS AND INHALING CONTENTS CAN BE
HARMFUL OR FATAL.

Exposure Controls

Respiratory Protection:NIOSH/MSHA-APPROVED RESPIRATOR APPROPIATE FOR
EXPOSURE OF CONCERN IF TLV IS EXCEEDED.
Ventilation:LOCAL EXHAUST TO MAINTAIN EXPOSURE BELOW TLV.
Protective Gloves:POLYETHYLENE, NEOPRENE.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:PROTECTIVE CLOTHING AND EQUIPMENTE AS
REQUIRED TO PREVENT PROLONGED CONTACT.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.LAUNDER
CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
KEY1:F1. THIS IS PART C OF A 3-PART PRODUCT. FOR OTHER PARTS, SEE PNI A
AND B, SAME NSN. THIS NSN HAS BEEN CANCELLED, AND REPLACED WITH NSN
6850-00-142-8840.

Chemical Properties

HCC:V3
Vapor Pres:45 PSIG
Vapor Density:>1
Spec Gravity:<1
Evaporation Rate & Reference:<1 (ETHER = 1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:RED LIQUID. AROMATIC ODOR.
Percent Volatiles by Volume:98

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:OPEN FLAMES, SPARKS, ELECTRICAL ARCS.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
INCOMPLETELY BURNED CARBON PRODUCTS.

Disposal

Waste Disposal Methods:CONTACT YOUR LOCAL ENVIRONMENTAL OFFICER.DO NOT
PUNCTURE OR INCINERATE CONTAINER.DISPOSE OF IN ACCORDANCE WITH
FEDERAL,STATE AND LOCAL ENVIRONMENTAL REGULATIONS.FULL OR PARTIALLY
FILLED CONTAINERS ARE CONSIDERED HAZARDOUS WASTE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.